Hydraulic stability

Cubipod hydraulic stability has been tested in many European hydraulic engineering laboratories, such as the following:

Universities

  • Laboratorio de Puertos y Costas de la Universidad Politécnica de Valencia (Spain).

  • Laboratorio de la Universidad de Aalborg (Denmark).

  • Laboratorio de Puertos de la Universidad Politécnica de Madrid (Spain).

  • Laboratorio de Puertos y Costas de la Universidad de A Coruña (Spain).

  • Instituto de Hidráulica Ambiental de la Universidad de Cantabria (Spain).

State research centers

  • CEDEX: Centro de Estudios y Experimentación de Obras Públicas (Spain).

Private research centers

  • Instituto de Hidrodinámica Aplicada (INHA): hydraulic stability tests on single-layer and double-layer Cubipod armor

  • Instituto de Hidrodinámica Aplicada (INHA)

Hydraulic stability test Tp=18s Hs=6.5m
Hydraulic stability test Tp=18s Hs=9.5m

Overtopping test in a single layer
Overtopping test in a double layer